What was found
DURING THE STRUCTURAL INSPECTION IT WAS FOUND AT FORWARD FUSELAGE LOWER SKIN PANEL, WITH DENT OUT ALLOWABLE DAMAGE LIMITS PER SRM, LOCATED AT FR9+65MM, 35MM ABOVE STRG-21R, THE DAMAGE WAS REPAIRED INSTALLING EXTERNAL REPAIR DOUBLER AS PER ERJ-190 PART II SRM 53-10-01 REPAIR 62 AND SRM 51-75-17.