What was found
DURING SPECIAL DETAILED INSPECTION ON SERVICE DOOR FRAME FR16 AS PER TASK CARD 531153-02-2-001 INSTRUCTIONS, IT WAS FOUND AT FWD SERVICE DOOR AREA, FR16 DOUBLE JOGGLE AREA, FASTENER HOLE “B” WITH CRACK INDICATION. THE DAMAGE REPORTED WAS REPAIRED IAW TO AIRBUS REF. 81019156.