What was found
DURING THE STRUCTURAL INSPECTION PER TASK CARD Nº: 572066-01-1-002 MPD, IT WAS FOUND AT RH WING, T/E FALSE REAR SPAR OVERHANG AREA BETWEEN STA 3592 AND STA 4012 OVERHANG TOP SKIN LOWER SURFACE WITH CORROSION AND LIGHTNING STRIKE ON UPPER SURFACE. THE RESULTING BLEND OUT AFTER CORROSION REMOVAL WAS FOUND OUT OF THE SRM LIMITS. DUE TO THIS FACT, DETAILS WERE SENT TO AIRBUS ASKING FOR REPAIR INSTRUCTIONS AND FINAL APPROVAL AND FINAL APPROVAL UNDER AIRBUS DOSSIER 81037170 AND COOPESA'S ENGINEERING ORDER COO-EO-2022-15251 REV 01 .