What was found
DURING THE STRUCTURAL INSPECTION PER TASK CARD Nº: 572062-01-1-002 MPD, IT WAS FOUND AT RH WING, T/E FALSE REAR SPAR OVERHANG AREA BETWEEN RIB 6 AND RIB 7, RIB 15, RIB 21 AND RIB 22 OVERHANG TOP SKIN LOWER SURFACE WITH CORROSION. THE RESULTING BLEND OUTS AFTER CORROSION REMOVAL WERE FOUND OUT OF THE SRM LIMITS. DUE TO THIS FACT, DETAILS WERE SENT TO AIRBUS ASKING FOR REPAIR INSTRUCTIONS AND FINAL APPROVAL, UNDER AIRBUS DOSSIER 81068690.