What was found
DURING THE ACCOMPLISHMENT OF ALLEGIANT TASK 53-210-003_P1-OP-UP-NDT INSPECTION (RELATED TO AD 2020-17-03), IT WAS FOUND THE COCKPIT, WINDSHIELD CENTER POST, LOWER ATTACHMENT AREA, CONTINUITY FITTINGS LH AND RH CRACKED.
THE DAMAGES WAS FOUND BEYOND SRM LIMITS. ALLEGIANT WAS CONTACTED TO REQUEST REPAIR INSTRUCTIONS. ALLEGIANT PROVIDED REPAIR INSTRUCTIONS UNDER ERO NUMBER R5311-0175 AND REPAIR WAS DOCUMENTED UNDER COOPESA JOB: A1M148 (ITEM 2-36)