As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
1. DURING STRUCTURE INSPECTION, WE FOUND AT THE RH FORWARD FLOOR TRACK WITH CORROSION AT THE UPPER FLANGE BETWEEN FR 12 AND FR 14 AND BETWEEN FR 17 AND FR 18. WAS REPAIRED FOLLOWING EMBRAER REPAIR INSTRUCTIONS UNDER ETD2022-190-037191 REV / AND APPROVED ON ANAC F-200 FORM PROVIDED BY EMB.