What was found
DURING THE STRUCTURE INSPECTION PER ALLEGIANT ENGINEERING ORDER E5316-0002 REV00 WE FOUND FOUND AT UPPER FUSELAGE FR20, RH SIDE, AT LEVEL OF DOOR STOP #1, INTERCOSTAL FITTING WITH CRACKS. CORRECTIVE ACTION: PERFORMED PERMANENT REPAIR PER AIRBUS INSTRUCTIONS STATED IN COOPESA ENGINEERING ORDER NUMBER COO-EO-2022-15009 R00 DATED 02-01-2022. SEE COOPESA WORK ORDER: A1K303, ITEM 2-28 FOR DETAILS.