What was found
DURING THE STRUCTURAL INSPECTION PER ALLEGIANT TASK CARD E5311-0019_P1-OP-UP-NDT, IT WAS FOUND AT DOUBLE JOGGLE FR16/FR20 INSP/MOD C/W AD 2022-08-08 EO E5311-0019 R00. DUE TO THERE IS NOT SRM AVAILABLE TO PERFORM PERMANENT REPAIR, WAS PERFORMED PER ALLEGIANT E5311-0019 REV 00 AD-2022-08-08 LH SIDE FR 16 REDESIGN OF THE ACOMPLISHED. SEE COOPESA ITEM 22-25