What was found
PLEASE NOTE THAT DURING THE STRUCTURAL INSPECTION AS PER ALLEGIANT INSPECTION TASK ZL-145-01-1-001 MPD TASK, SEVERAL CORROSION ON CENTER WING BOX TOP SKIN UPPER SURFACE BETWEEN FR41 AND FR42 AND +Y 1292 AND RIB 1 DATUM WAS FOUND, COMMON TO APU FUEL FEED FITTING BASE CONTOUR. CORRECTIVE ACTION: DAMAGE REPORT WAS SENT TO AIRBUS, AND THE REPAIR INTRUCTIONS WERE HANDLED UNDER AIRBUS DOSSIER 81176407 AND COOPESA JOB A1N004, NRI 2-30