What was found
FRAME 68, R/H SIDE, STOP FITTING #1 AREA, I/B & O/B LOWER HOLES HAS BEEN FOUND CRACKED.CORRECTIVE ACTION: PERFORMED PERMANENT REPAIR I.A.W A320 SRM TASK 53-41-12-300-008 PARAG 2.A FIG 001, FIG 002, FIG 003 AND SRM TAS 53-41-12-300-011 PARAG 2.A TABLE 002 FIG 001, FIG 002 AND FIG 008 SHEETS 1,2 & 3, REV 144 DATED 02-01-2023. THIS IS A MAJOR PERMANENT REPAIR CATEGORY B. NOTE: FOR REQUIRED INSPECTIONS SEE NRI 2-53 AND NRI 2-45.