What was found
DURING THE STRUCTURAL INSPECTION PER WORK CARD Nº: 531166-01-2-001, IT WAS FOUND THE CREW DOOR SILL BEAM WITH TWO AREAS CORRODED. THE FIRST OPTION WAS REPLACING THE PART HOWEVER, IT IS NOT AVAILABLE. DUE TO THIS FACT, DETAILS WERE SENT TO AIRBUS ASKING FOR REPAIR INSTRUCTIONS AND FINAL APPROVAL.AIRBUS PROVIDED REPAIR INSTRUCTION UNDER DOSSIER 81223470. COOPESA PERFORMED REPAIR UNDER EO COO-EO-2023-17746-R00 THE RPAIR WAS DOCUMENTED UNDER COOPESA JOB A1N083 ITEM2-16).