DURING ACCOMPLISHMENT OF ALLEGIANT ENGINEERING ORDER E5311-0018 FR 16 RH DOUBLE JOGGLE AREA AT LEVEL OF DOOR STOP # 7 HOLES # 1,#2,#4 THRU #8, #A THRU D AND AT LEVEL OF DOR STOP #1 HOLES #9,#10,#12 THRU #19 WERE FOUND GREATER THAN THE STARTING HOLE DIAMETER FOR COLD WORK PROCESS. AIRBUS WAS CONTACTED TO REQUEST REPAIR INSTRUCTIONS. AIRBUS PROVIDED REPAIR INSTRUCTIONS UNDER DOSSIER 81014204. COOPESA PERFORMED REPAIR INSTRUCTIONS IAW COOPESA ENGINEERING ORDER COO-EO-2024-19314-R02.