What was found
DURING ACCOMPLISHMENT OF THE ALLEGIANT ENGINEERING ORDER E5311-0019, UPPER FUSELAGE FR16 LHS DOUBLE JOGGLE AREA AT LEVEL OF DOOR STOP # 1 HOLES #10,#12,#14;#15,#17 THRU #19 WERE FOUND GREATER THAN THE STARTING HOLE DIAMETER FOR COLD WORK PROCESS WERE FOUND. PERFORMED PERMANENT REPAIR AT UPPER FUSELAGE FR16 LHS DOUBLE JOGGLE AREA IAW EO COO-EO-2024-20736-R02 AND RDAF 81452785/004/2024 # A APPROVED UNDER ERO # R5311-035-R00. THIS IS A MAJOR REPAIR PERMANENT CAT B. THIS REPAIR WAS DOCUMENTED UNDER JOB A1P187 ITEM 2-64.