As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING THE ACCOMPLISHMENT OF SB190-57-0056, WERE FOUND 5 EXISTING FASTENER HOLES WITH OVERSIZED DIAMETER (LOCATED AT SPAR I AND RIBS 8 AND 9). THIS CONDITION WAS REPORTED TO EMB FOR REPAIR INSTRUCTIONS. THIS CONDITION WAS REPAIRED PER ETD2025-190-922232 AND DOCUMENTED UNDER THE COOPESA E.O. COO-EO-2025-22482 DTD JUN 08 2025.