What was found
DURING A STRUCTURAL INSPECTION, A DENT WAS IDENTIFIED ON THE CENTER FUSELAGE LOWER SKIN AT FRAME 27 AND BETWEEN STRINGERS 27LH-28RH. ACCORDING TO DOCUMENTATION FROM THE PREVIOUS OPERATOR, THE DENT WAS ASSESSED UNDER REFERENCE ETD2017-190-094601. THE AREA IS CURRENTLY IN POOR CONDITION: THE DENT WAS NOT PROPERLY RECONTOURED, AND A CREASE IS PRESENT. ADDITIONALLY, THE DOCUMENTATION LACKS CRITICAL INFORMATION, SUCH AS WHETHER THE SHEAR CLIPS WERE REPLACED OR NOT. THE CONDITION REPORTED WAS REPAIRED IAW ETD2025-190-930382.