What was found
DURING STRUCTURAL INSPECTION, SKIN WITH NICKS WERE FOUND AT FWD FUSELAGE FROM FR18+85MM / FR19+150MM, BTWN STR26L / 27L+80MM. THE NICKS REPORTED EXCEED THE LIMITS FOR NON-SIGNIFICANT DAMAGE AND THE ALLOWABLE DAMAGE PER SRM53-10-01 AD51, DUE TO THEIR LOCATION WITHIN A NON-ALLOWED AREA. THE CONDITION REPORTED WASREPAIRED IAW ETD2025-190-930779, AND DOCUMENTED PER COOPESA COO-EO-2025-23380, UNDER JOBA1Q219 NRI 21-83.