As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CUSTOMER REPORTS LIGHTNING STRIKE DAMAGE AFFECTING THE CENTER FUSELAGE III SKIN, LOCATED AT FR74 AND STR 28L. THE DAMAGE WAS REMOVED BY BLENDING THE AFFECTED AREA IN ACCORDANCE WITH SRM 51-10-03, BLEND-OUT TYPE D. AFTER EVALUATION, IT WAS DETERMINED THAT THE BLEND-OUT IS OUTSIDE THE LIMITS SPECIFIED IN SRM 53-23-01 AD51. THIS CONDITION REPORTED WAS REPAIRED IAW ETD2026-190-001961 DTD JAN 31 2026 AND DOCUMENTED UNDER COOPESA EO COO-EO-2026-23837-R00. JOB A1Q328 ITEN 21-11