What was found
DURING THE STRUCTURAL INSPECTION, CORROSION SPOTS WERE FOUND ON THE EXTERNAL SKIN SURFACE BETWEEN FR16-17, AND BETWEEN STRINGERS 26R-27R, AROUND THE ANTENNA CUT-OUT AREA. THE CORROSION WAS REMOVED BY BLEND-OUT IN ACCORDANCE WITH SRM PART II 51-10-03 REQUIREMENTS. THIS CONDITION REPORTED WAS REPAIRED IAW ETD2026-190-004184 DTD MAR 16 2026 AND DOCUMENTED UNDER COOPESA EO COO-EO-2026-24127-R00 DTD MAR 17 2026. JOB A1Q349 ITEM 21-55.