What was found
COOPESA REPORTS THAT A FIRE OUTBREAK OCCURRED INSIDE THE FORWARD FUSELAGE, SPECIFICALLY WITHIN THE FORWARD CARGO COMPARTMENT NEAR THE INTERNAL SIDE OF THE EXTERNAL AC POWER RECEPTACLE. FROM THE MOMENT THE SPARK AND FIRE BEGAN TO THE INITIATION OF COOPESA’S EMERGENCY RESPONSE, APPROXIMATELY 30 SECONDS PASSED. THE COOPESA EMERGENCY RESPONSE TEAM ACCESSED THE AFFECTED AREA BY THE FORWARD CARGO COMPARTMENT AND, USING A KIDDE 90 MULTI-PURPOSE ABC DRY CHEMICAL FIRE EXTINGUISHER, BEGAN SUPPRESSING THE FIRE, WHICH WAS IMMEDIATELY FULLY EXTINGUISHED. ONCE THE SITUATION WAS UNDER CONTROL, A THOROUGH CLEANING AND DAMAGE ASSESSMENT WAS PERFORMED REGARDING THE AFFECTED STRUCTURAL COMPONENTS CLEARY AFFECTED BY THE HEAT AND SMOKE OF THE FIRE FLAMES. AS A RESULT OF THE DAMAGE ASSESSMENT, COOPESA HAS PERFORMED A DAMAGE MAPPING THAT INCLUDES REMAINING THICKNESS AND ELECTRICAL CONDUCTIVE TESTS. THIS CONDITIONREPORTED WAS REPAIRED IAW ETD2026-190-007358 DTD MAY 15 2026 AND DOCUMENTED UNDER COOPESA EO COO-EO-2026-24572-R00 DTD MAY 29 2026.