What was found
DURING THE ACCOMPLISHMENT OF ALLEGIANT TASK A32X-E5316-0002 RELATED TO AD 2022-02-11 / SB53-1330/SB53-1339, IT WAS FOUND AT FR16/20 LH DOOR STOP FITTING FASTENER HOLES AREA WITH CRACK INDICATION AND FR16 RH DOOR STOP FITTING FASTENER HOLE AREA WITH CRACK INDICATION AT THE FOLLOWING POSITIONS:1- LH SIDE-FR16 AT DOORSTOP FITTING # 7, INTERCOSTAL FITTING HOLES WITH CRACK INDICATIONS. 2- LH SIDE- FR20 AT DOORSTOP FITTING # 1 WEB FRAME CRACKED. 3- RH SIDE FR16 AT DOORSTOP FITTING # 1 INTERCOSTAL FITTING HOLE WITH CRACK INDICATIONS. DUE TO IT, THIS CONDICION WAS REPORTED TO AIB AND REPAIRED IAW AIB MEESAGE #81708351/003 DTD DEC 12 2025 AND PER SRM 53-11-12-300-011 REV. 154 GUIDELINES, UNDER JOB A1Q235 AND ITEM 2-44.