What was found
DURING THE ACCOMPLISHMENT OF REF. A, THE PYLON LOWER LINK FITTING OUTBOARD LUG FIXED BUSHINGS WERE FOUND WITH WEAR. AFTER REMOVAL OF THE BUSHINGS FOR REPLACEMENT, LOCALIZED CORROSION WAS DETECTED BETWEEN THE LUG SURFACE AND THE PRODUCTION REINFORCEMENT ANGLE. FOLLOWING REMOVAL OF THE REINFORCEMENT ANGLE, THE CORROSION WAS ELIMINATED. HOWEVER, THIS CONDITION WAS REPORTED TO EMB FOR REPAIR INSTRUCTIONS. EMB EMITTED THE ETD2026-190-014493 REV. A AND WAS DOCUMENTED IN THE COOPES EO #COO-EO-2026-24899, UNDER JOB A1Q358 ITEM 4-108