What was found
FRA - LEFT SIDE WING OVERHEAT LIGHT CAME ON DURING CLIMB-OUT AT FL 240. FOUND DUCT SEAL AT LE MID SECTION BLOWN. REPLACED, REALIGNED AND RETORQUED DUCT ASSY AND SUPPORT MOUNTS. DURING TROUBLESHOOTING FOUND SUPPORT BRACKETS BROKEN. FABRICATED BRACKETS PER ECRA 481-36-011-3 PART 1. OPS AND LEAK CHECKED OK. JFK, INSTALLED REPLACEMENT SUPPORT BRACKETS PER ECRA 481-36-011-3 PART 2. (M)