What was found
C1-CHECK, UPPER L/E FOUND BULGED AREA AT WS 1390 JUST AFT OF NR 3 VC FLAP AREA IN 2 LOCATIONS. WS 1380-1400 BLENDED OUT, AND NDT INSPECTED SKIN AND OPEN HOLES. FLAP-PEENED, ALODINED AND PRIMED. ORIGINAL FASTENERS REPLACED WITH .0625 INCH OVERSIZED HI-LOCK FASTENERS IN INTERFERENCE FIT HOLES. CAP SEAL FASTENERS FUEL TANK. REF EVR-HKG-00-00083F/00157H/00141F/00159H/00143F/00162H/00144F/FAA 8110-3/R57-25-34484. (M)