What was found
HKG-HAECO - FOUND FLOORBEAM LEFT BS 340 CRACKED AT FRAME FASTENER HOLE, RUNNING OUTBOARD 4TH FASTENER HOLE. REPLACED LEFT BS 340 FRAME BETWEEN STRINGER 0-14L PER EO 53-747-1143-91 REV E AND DWG 624U0003 SH 8D. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HKG-HAECO - FOUND FLOORBEAM LEFT BS 340 CRACKED AT FRAME FASTENER HOLE, RUNNING OUTBOARD 4TH FASTENER HOLE. REPLACED LEFT BS 340 FRAME BETWEEN STRINGER 0-14L PER EO 53-747-1143-91 REV E AND DWG 624U0003 SH 8D. (M)