What was found
PER N5349, LT ENTRY DOOR JAMB AFT STOP 4, BS 200 CRACKED AT DOOR STOP HOLE. REMOVED DAMAGE, INSTALLED, FABRICATED DOUBLERS & FILLERS PER SRM 53-05, PGS 546, 551, 552. REPEAT INSPECTION PER W/C N5343 AT OR BEFORE 28,000 CYCLES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PER N5349, LT ENTRY DOOR JAMB AFT STOP 4, BS 200 CRACKED AT DOOR STOP HOLE. REMOVED DAMAGE, INSTALLED, FABRICATED DOUBLERS & FILLERS PER SRM 53-05, PGS 546, 551, 552. REPEAT INSPECTION PER W/C N5343 AT OR BEFORE 28,000 CYCLES.