What was found
4 EA HOLES HAVE BREAKUP CONDITION ON CENTER OF STRINGER END FITTING NR 23 AT THE BS 1241 AFT RT SIDE. REMOVED AND INSTALLED NEW END FITTING PER B747 SRM 51-30-02 PAGE 8-9 AT BS 1241 STR NR 23R. FABRICATED AND INSTALLED NEW STRINGER NR 23 RT STA 1241 PER B747 SRM 51-30-02 PAGES 8-9. FABRICATED AND INSTALLED NEW INTERCOSTAL WEB AT BS 1241-1258 STR, 23R PER B747 SRM 51-30-02 PAGES 2-3 AND B747 SRM 51-30-02 PAGES 8-9, REPLACED STR 23 AT BS 1241-1265 RT.