What was found
FRAME STA. 380L CRACKED FLANGE AT STR 22 CUTOUT. REMOVED DAMAGED AND FABBED AND INSTALLED REPAIR IAW SRM 53-10-04 PG. 43-45 AND 53-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME STA. 380L CRACKED FLANGE AT STR 22 CUTOUT. REMOVED DAMAGED AND FABBED AND INSTALLED REPAIR IAW SRM 53-10-04 PG. 43-45 AND 53-10-02.