What was found
BS 340 FLOORBEAM UPPER CHORD HORIZONTAL AFT FLANGE RBL 52 FLOOR PANEL ATTACH HOLE CRACKED RUNNING FWD APPROX 0.040 INCH. DEFECTIVE FLOORBEAM UPPER CHORD REPAIRED AS PER S/B 747-53A2431 FIG 10 (HORIZONTAL AFT FLANGE RBL 52).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 340 FLOORBEAM UPPER CHORD HORIZONTAL AFT FLANGE RBL 52 FLOOR PANEL ATTACH HOLE CRACKED RUNNING FWD APPROX 0.040 INCH. DEFECTIVE FLOORBEAM UPPER CHORD REPAIRED AS PER S/B 747-53A2431 FIG 10 (HORIZONTAL AFT FLANGE RBL 52).