What was found
DIS-BOND OF INNER PANEL SKIN AT TITANIUM AREA ON NR 5 MOVABLE FLAP-TRACK FAIRING. X-RAY INTERSECTION OF ADJACENT AREA AND SUB-STRUCTURE, CONFIRM ALL DAMAGE. REMOVE DAMAGE SECTION OF TITANIUM SCRAP WITH 10 PLIES 9-8 INCLUDED 2 EXTRA FIBERGLASS PLIES COMPLETELY COVERING GRAPHITE PLIES WITH 0.5 INCH OVERLAP. INSTALLED FASTENERS WITH BMS 5-95 AND ASSEMBLE BRACKETS WITH BMS 5-95, REPLACE DAMAGED INSERTS.