What was found
FUSELAGE INTERIOR FRAME TO FRAME ANGLE STATION 960 STRINGER 15L HAS MISDRILLED FASTENER HOLES. DAMAGE REMOVED, NDT AREA, FABRICATED AND INSTALLED REPAIR PER ECRA 4887-53-044-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE INTERIOR FRAME TO FRAME ANGLE STATION 960 STRINGER 15L HAS MISDRILLED FASTENER HOLES. DAMAGE REMOVED, NDT AREA, FABRICATED AND INSTALLED REPAIR PER ECRA 4887-53-044-2.