What was found
HKG - DURING C-CHECK, DURING ACCOMP OF EO 53-747-1513-98B AND SB 747-53A2390 PLAN B, BS 1480 BULKHEAD INSPECTION MOD, LEFT SIDE (3 EACH) FASTENER HOLES FOUND CRACKED, NR 23 AND NR 25 IN WEB SPLICE PLATE AND NR 6 LONGERON EXTENSION FITTING, NRC 7193-7195, 7185 AND 7332. ALL HOLES CLEANED AND CLEARED WITHIN SB LIMITS. (M)