What was found
EAC-MZJ - STA 480 BETWEEN STR'S 8L-9L FORWARD SIDE OF FRAME NEAR FRAME SPLICE HAD SMALL AREA OF EXFOLIATION CORROSION. REPAIRED PER ECRA 479-53-120-2. BLENDED CORROSION, FLAP PEENED, AND INSTALLED REPAIR SPLICE. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EAC-MZJ - STA 480 BETWEEN STR'S 8L-9L FORWARD SIDE OF FRAME NEAR FRAME SPLICE HAD SMALL AREA OF EXFOLIATION CORROSION. REPAIRED PER ECRA 479-53-120-2. BLENDED CORROSION, FLAP PEENED, AND INSTALLED REPAIR SPLICE. (X)