What was found
STA 1700 TO 1740 LBL 33 SEAT/TIE DOWN TRACK CHAFED. DAMAGED AREA REMOVED PER SRM 51-10-01 NDT CHECKED PER PT4/51-00-00 ORIG THICKNESS 0.170 INCH REMAINING 0.140 INCH BEYOND SRM 53-10-01 LIMITS. FASTENERS REMOVED FROM 1700 TO 1770 PER SRM 51-30-02. DAMAGED SEAT TRACK CUT AS PER SRM 53-10-05 FIG 1A. NDT C/O PER PT6/51-00-00, NO CRACK. FABRICATED REPAIR PART STA 1710-1770 PER SRM 53-10-05 FIG 1A. HOLES TRANSFERRED PER SRM 51-30-05. REWORKED STRAPS PER SRM 53-10-05 C/O. HEAT TREATMENT PER BAC 5602. ALODINED PER BAC 5719, PRIMERED PER AMM 51-24-01. REPAIR PARTS INSTALLED PER SRM 51-30-02 PAR 4 SCREWS INSTALLED PER AMM 20-51-01.