What was found
MAIN DECK STA 2360 RBL 11 FLOOR SUPPORT WEB FOUND CRACK. CRACKED SUPPORT WEB REMOVED AT STA 2360 RBL PER SRM 51-30-02. FABRICATED NEW SUPPORT PER DWG 65B06154. ALODINED PER BAC 5719, PRIMERED PER AMM 51-24-01. NEW SUPPORT WEB INSTALLED PER SRM 51-30-02 PARA 4.