What was found
MAIN DECK FLOORBEAM BS 1700 BL 0 DRILL STRUT NEXT TO FASTENER HOLE. REMOVED DAMAGE, FABRICATED REPAIR STRAP AND FILLER AND STIFFENER PER SRM 53-10-07 FIG 2 AND 51-30-02 PG 8-9
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOORBEAM BS 1700 BL 0 DRILL STRUT NEXT TO FASTENER HOLE. REMOVED DAMAGE, FABRICATED REPAIR STRAP AND FILLER AND STIFFENER PER SRM 53-10-07 FIG 2 AND 51-30-02 PG 8-9