What was found
TOP FLANGE OF AFT PIT FLOOR BEAM IS BROKEN BS 1820 7.5 INCHES I/B OF DOOR THRESHOLD. REMOVED DAMAGED AREA, FABBED AND INSTALLED REPAIR PER B747 SRM 51-40-04 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TOP FLANGE OF AFT PIT FLOOR BEAM IS BROKEN BS 1820 7.5 INCHES I/B OF DOOR THRESHOLD. REMOVED DAMAGED AREA, FABBED AND INSTALLED REPAIR PER B747 SRM 51-40-04 FIG 2.