What was found
MAIN DECK NR4 DOOR AFT LOWER CORNER FOUND CRACK. FASTENERS REMOVED AS PER SRM 51-40-02 NDT PENGRANT INSP CARRIED OUT AS PER BSOPM 20-20-02. CONFIRMED CRACKED END STOP DRILLED AS PER SRM 52-10-02 FIG 101 REPAIR 2, ET CARRIED OUT AS PER PT6/51-00-00, NO CRACK NOTED, FABRICATED NEW REPAIR PARTS AND FILLERS AS PER SRM 51-10-02 FIG 201 REPAIR 2, LOCATED AND DRILLED AS PER SRM 51-40-05, ALODINED AS PER BAC5719 REV Y, PRIMED AS PER AMM 51-24-11, INSTALLED REPAIR AS PER SRM 51-40-02 & 52-10-02 FIG 201 REPAIR 2.