What was found
RT LOWER FUSELAGE AT STA 480, STR-41R AREA FOUND 1 EA DENT MARK. PAINT STRIPPED AS PER AMM 51-21-01, ET CARRIED OUT AS PER PT6/51-00-01 FIG 23 FOUND CRACK, THE REPAIR AREA DAMAGE OUT OF LIMITS AS PER SRM 53-00-01, FIG 101, CUT OUT DAMAGE AREA AS PER SRM 53-00-01, REPAIR PARTS FABRICATED AS PER SRM 53-00-01 R-1, FASTENER HOLES DRILLED AS PER SRM 53-00-01 R1, ET CARRIED OUT AS PER PT 6/51-00-00 FIG 23, NO CRACK ALODINED AS PER BAC5719-REV Y, PRIMED AS PER AMM 51-24-11 REPAIR PARTS & FASTENERS INSTALLED AS PER SRM 53-00-01 R1.