What was found
NR 1 ENG COMPRESSOR STALLS DURING INITIAL DESCENT, DOES NOT RESPOND TO THROTTLE MOVEMENT. ENG SHUTDOWN. EGT AROUND 810 DEGREES WITH THROTTLE AT IDLE. ATTEMPTED ENG START ABOVE FL 200 STALL DID NOT CLEAR. BELOW FL 200 ENG STARTED. ALL PARAMETERS WERE NORM. INSPECTED INLET, EXHAUST AND 3.5 BLEEDS FOR METAL PARTICLES NOTHING ABNORM NOTED. PERFORMED PWR RUN PER MM 71-00-00, CHECKING HI-STAGE, TANDEM BLEED AND AIR GROUND LOGIC BLEED OPERATION. ALL NORM. PERFORMED EVC TRACK CHKS AND PT2 LEAK CHK AND FOUND OK. CHK'D EVC UNISON RING, PT3 AND PS3 SENSE LINE FOR SECURITY AND FOUND OK. REPLACED EVC PH FILTER AND PRBC VALVE AS PRECAUTIONARY. PERFORMED PWR RUN PER 71-00-00, ENG T/S, ENG OPERATION WAS NORM. (M)