What was found
SAT - FORWARD CARGO BAY FRAME 362 FLOOR SUPPORT IS CORRODED AT STRINGER 28R. FABRICATED AND INSTALLED FLOOR SUPPORT CHANNEL FROM BS 218 TO 285 AND 285 TO 362 PER SRM 53-21-0, 53-01 FIGURE 2 AND 51-21-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAT - FORWARD CARGO BAY FRAME 362 FLOOR SUPPORT IS CORRODED AT STRINGER 28R. FABRICATED AND INSTALLED FLOOR SUPPORT CHANNEL FROM BS 218 TO 285 AND 285 TO 362 PER SRM 53-21-0, 53-01 FIGURE 2 AND 51-21-3. (M)