What was found
SAT - FORWARD CARGO BAYFRAME 237 FLOOR SUPPORT STRUT AT LONGERON 24R IS CRACKED. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT STRUT AT FR 237 LONGERON 24R PER DAC DRAWING 5922079 AND SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAT - FORWARD CARGO BAYFRAME 237 FLOOR SUPPORT STRUT AT LONGERON 24R IS CRACKED. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT STRUT AT FR 237 LONGERON 24R PER DAC DRAWING 5922079 AND SRM 51-30-2. (M)