What was found
MZJ - DURING C-CHECK INSPECTION, DISCOVERED DRILL BIT DAMAGE TO BOTH THE PRIMARY AND SECONDARY 9G NET BRACE AT RIGHT STATION 218 AND LEFT AND RIGHT STATION 256. DAMAGE WAS REPAIRED PER EVERGREEN INTERNATIONAL AIRLINES ENGINEERING CHANGE, REPAIR AUTHORIZATION NR ECRA 932-53-031-2. (M)