SAT - DURING C-6 INSPECTION, AFT CARGO COMPARTMENT, STRINGER 30, SPLICE PLATE IS HEAVILY CORRODED AT STATION 927 AT STRINGER SPLICE PLATE. REMOVED AND REPLACE STRINGER 30, STATION 927 SPLICE FITTING IAW SRM 51-30-5 AND 51-10-3. (M)