What was found
SAT - DURING C-6 INSPECTION, FOUND MAIN CABIN STRINGER 17R IS CRACKED AT STATION 985. REMOVED DAMAGED LONGERON RIGHT SIDE, STATION 960 THROUGH 996 IAW SRM 53-02 FIGURE 2. FABRICATED AND INSTALLED RIGHT REPAIR PARTS IAW SRM 51-30-2 AND 53-02 FIGURE NR 2 FABRICATED FROM T6 EXTRUSION, PART NR 7637813-3, PO 336332, 14 INCH LONG, TREATED AREA ALODINE AND PRIMED IAW SRM 51-10-3. FABRICATED PART NR 2777922-4 FROM T6 EXTRUSION PO 120600, TREATED AREA WITH ALODINE AND PRIMED IAW SRM 51-10-3. (M)