What was found
SAT - DURING C-6 INSPECTION, FOUND EXFOLIATION CORROSION ALONG FLOORBEAMS IN AFT E/E COMPARTMENT STATIONS 160 TO 220 LONGERON 18R. REMOVED AND REPLACED T-ANGLE PER SRM 51-30-2. (M)