As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SAT - DURING C-6 INSPECTION, FOUND AFT CARGO STRINGER 30 SPLICE PLATE IS HEAVILY CORRODED AT STATION 952. REMOVED AND REPLACED SPLICE PLATE PER SRM 57-01 AND 57-30-02 RIGHT CANTED KEEL FORWARD ATTACH FITTING PER SRM 57-01 AND 57-30-2. (M)