SAT - DURING C-6 INSPECTION, FOUND FLOOR SUPPORT ANGLE CLIP CORRODED AT STATION 160, LBL 40. REMOVED, FABRICATED AND INSTALLED CLIP PER SRM 51-10-4 AND 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAT - DURING C-6 INSPECTION, FOUND FLOOR SUPPORT ANGLE CLIP CORRODED AT STATION 160, LBL 40. REMOVED, FABRICATED AND INSTALLED CLIP PER SRM 51-10-4 AND 51-30-2. (M)