What was found
MZJ - DURING C-CHECK INSPECTION, DISCOVERED EXFOLIATION CORROSION IN THE RIGHT LOWER WING SKIN STATION 1000 IN THE LOWER SKIN PANEL SPLICE AREA. THE CORROSION EXTENDED UNDER A WING PANEL SPLICE STRAP (UPPER SURFACE OF THE WING PLANK). REMOVED CORROSION, ROTOPEENED, NDT INSPECTED, FABRICATED AND INSTALLED REPAIR FILLER WET WITH SEALANT. ACCOMPLISHED IAW EIAA ECRA NR 479-57-089-2. (M)