What was found
HKG - DURING C5/D CHECK INSPECTION, DISCOVERED MAIN DECK TIE DOWN TRACK CROWN CORRODED AT STATION 2020 RBL 11. REPAIRED BY REPLACING TIE DOWN TRACK FROM BS 2010-2030. REPAIR ACCOMPLISHED IAW SRM 51-10-01, P/N BAC 1520-1682-717876511RK. (M)