What was found
STR 24R FROM STA 360 TO STA 330 HAS CORROSION. FABRICATED STR SPLICE, ALODINED, PRIMED, AND INSTALLED IAW B727 DRAWING 65-18420, B727 SRM 51-10-2, 51-30-2 AND 53-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STR 24R FROM STA 360 TO STA 330 HAS CORROSION. FABRICATED STR SPLICE, ALODINED, PRIMED, AND INSTALLED IAW B727 DRAWING 65-18420, B727 SRM 51-10-2, 51-30-2 AND 53-10-3.